< img src="https://mc.yandex.ru/watch/104548671" style="position:absolute; left:-9999px;" alt="" />

Home > Blogs > The Business and Implementation of Membrane Regeneration: Real-World Experiences from Europe, the U.S., and South America

The Business and Implementation of Membrane Regeneration: Real-World Experiences from Europe, the U.S., and South America

Oct 12,2026Reporter: DONGSHENG

Table of Contents:

  1. Membrane dissection is the first step in determining whether a membrane can be reused.

  2. Cleaning and structural integrity represent the industry’s largest blind spots

  3. Downgrading involves engineering parameters for the transition from RO to UF/NF

  4. Key Differences in Regional Practices

  5. Common Operational Pitfalls


Membrane recycling has already established a commercially viable model in Europe. Ecomemb is Europe’s first company dedicated to the sustainable regeneration of reverse osmosis membranes. Incubated in 2022 by the LEQUIA research group at the University of Girona in Spain, its core technology restores retired membranes to their original design specifications rather than downgrading their use. The company has already processed over 300 membrane elements for ten industrial facilities in Spain, with applications ranging from leachate treatment to drinking water production. In the chemical and mining industries, more than 100 Ecomemb-regenerated membranes have been successfully deployed as replacements. The Saica Group, a paper manufacturer, began partially replacing its existing membrane elements with Ecomemb-regenerated membranes in October 2024 and has experienced no operational issues to date. In the field of leachate treatment, Telwesa was the first company in Spain to use regenerated membranes for leachate treatment and has over seven years of operational experience.


The key to Brazil’s success lies in low-cost implementation. Research conducted by UFMG focused specifically on rural water supply scenarios under the Programa �gua Doce framework, using recycled membranes to treat groundwater with high iron content. The acquisition cost per membrane was only $30.50, saving a small desalination plant approximately $1,954.80 annually. Brazil’s life cycle assessment provides a clear ranking: direct reuse and conversion into ultrafiltration membranes perform best in environmental and social dimensions, while component recycling is the least expensive option; all membrane recycling schemes outperform landfilling.


Chile faces the challenge of membrane selection under pressure to scale up. In seawater desalination applications, membrane replacement cycles typically range from three to five years, with annual replacement rates reaching as high as 20 percent. As of November 2025, the cities of Antofagasta and Mejillones were already relying entirely on reverse osmosis desalination for their water supply. A joint project between the Catholic University of the North in Chile and the University of Technology of Valparaíso (CCTVal) has clearly identified the core challenge: how to determine which membranes still retain sufficient structural integrity to undergo the regeneration process. CCTVal is designing an experimental module specifically to assess the structural condition of membranes prior to conversion.


It is worth noting that the industrial chain for membrane recycling extends beyond the membranes themselves. The metal support structures within membrane modules and the titanium anodes used in water treatment systems are also valuable components in the recycling chain. DONGSHENG has long served the water treatment and chlor-alkali industries in the field of industrial precious metal recycling, specializing in the recovery of materials such as titanium anodes, DSA anodes, titanium electrode grids, and MMO-coated anodes. The core of its recycling process involves separating the spent coating from the titanium substrate of the titanium anodes. After purification, the substrate achieves a purity of 90% to 99% and is reintroduced into high-end manufacturing processes. This process directly reduces the demand for titanium ore mining, with each metric ton of recycled titanium resulting in 10 to 12 metric tons fewer carbon emissions compared to the smelting of primary titanium. When water treatment plants replace membrane modules or upgrade electrochemical treatment units, decommissioned titanium anodes and the metal supports of membrane modules are often disposed of together. DONGSHENG’s recycling service can process both types of materials simultaneously, allowing water treatment plants to generate additional revenue from metal recovery in addition to membrane recovery.


Membrane dissection is the first step in determining whether a membrane can be reused.


Membrane dissection is the core method for assessing the residual value of decommissioned membranes. In practice, membrane dissection should be performed as soon as possible after the membrane elements are removed from the system; otherwise, the condition of the fouling layer and the membrane material will change, affecting the accuracy of the assessment. The ASTM D7601-19 standard covers the inspection, performance testing, and dissection analysis procedures for pressure-driven membrane elements.


There is established best practice for selecting which membrane to dissect. In seawater desalination systems, the first element in the first stage is the most representative of membrane fouling conditions, while the elements at the end of the string are most likely to be associated with scaling issues. A simple and effective on-site method for quickly assessing mechanical integrity is the bubble test: fully submerge the membrane element in water, introduce air at a pressure of 3 to 5 psi into the permeate tube, and observe whether bubbles escape from the membrane element. The presence of bubbles indicates mechanical damage to the membrane element, and it should not be included in the membrane recovery process.


A practical screening framework has been established: post-cleaning permeate flux, salt rejection, feed channel condition, and membrane integrity collectively determine whether a decommissioned membrane is worth including in the subsequent membrane recovery process. The industry has also recognized that the lack of standardized acceptance criteria remains the primary obstacle to the widespread adoption of membrane recovery.



Cleaning and structural integrity represent the industry’s largest blind spots


A key lesson is that cleaning can restore flux but accelerates the degradation of the polyamide active layer. A membrane may appear to have restored its flux after cleaning, but if the desalination layer has been irreversibly damaged, water quality will exceed standards within one to three months after being reinstalled. Research has clearly shown that the effect of cleaning on membrane performance is limited to extending service life; it cannot restore the membrane element to its original operating parameters. Therefore, membrane cleaning must be used as a diagnostic step as well, not merely as a restorative measure. The rate of flux recovery after cleaning and the extent of salt rejection loss are the core criteria for determining whether a membrane should remain in its original position, be downgraded for use, or be scrapped.


Cleaning strategies must be tailored to the type of contaminant. Acidic cleaning agents are most effective for inorganic scaling, while alkaline cleaning agents are required for organic and biological fouling. In practice, combined cleaning strategies are often more effective than single-agent cleaning. First, a combination of NaClO and NaOH is used to remove organic contaminants, followed by a secondary cleaning with citric acid to remove inorganic contaminants; this effectively restores the transmembrane pressure difference even under severe fouling conditions. Another practical tip involves ultrasonic assistance: combining ultrasonic cleaning with chemical cleaning can extend the membrane’s service life by 125 hours compared to using organic cleaning agents alone.


Downgrading involves engineering parameters for the transition from RO to UF/NF


Converting decommissioned reverse osmosis membranes into ultrafiltration or nanofiltration-grade membranes through oxidation with NaClO is currently the most mature membrane recovery method, with a processing cost of approximately $8 per membrane. When the NaClO exposure dose is below 20,000 ppm•h, the membranes primarily perform at the nanofiltration level; when the dose exceeds 30,000 ppm•h, the membranes are converted to the ultrafiltration level. Research from UFMG in Brazil has established a validated chemical cleaning protocol: first, treat the membranes with 0.1% NaOH for 12 hours at a pH of 11 to 12 and 25°C; then, treat them with 2% citric acid for 12 hours at a pH of 2.5 and 25°C. The goal is to restore permeability to at least 85% of that of new membranes. Prior to the formal cleaning, the membranes must be soaked in a 50% ethanol-water solution for 15 minutes to rewet them.


Performance data for the regenerated membranes: permeability of 44.3 L•m�²•h�¹•bar�¹, iron removal rate of 92.6%, color and turbidity removal rates exceeding 90%, an optimal operating pressure of just 0.5 bar, and energy consumption of 0.02 kWh per cubic meter of treated water. The acquisition cost per recovered membrane is only $30.50. Full-scale validation data is also available for the extreme pH and high-temperature regeneration route: a two-step protocol involving NaOH at 60°C followed by HCl restored the original water permeability to no less than 95% at the laboratory scale, with the loss in salt rejection rate controlled within 2.8%. Eight out of 12 full-scale elements met the reuse criteria, defined as a flux recovery of at least 95% and a retention rate loss of less than 3%. After 214 days of field testing, the absolute transmembrane pressure drop of the regenerated membrane elements rose to 0.85 bar, which is lower than the 0.93 to 1.02 bar observed in newly installed reverse osmosis elements; this is attributed to the pre-compaction and structural stabilization of the membranes following use.


In electrochemical water treatment systems, membrane recovery often occurs simultaneously with the recovery of titanium anodes. When water treatment plants upgrade their electrochemical oxidation units or replace membrane bioreactors, decommissioned titanium anodes and the metal support structures of membrane modules are generated as waste from the same batch. DONGSHENG’s recycling and processing line can simultaneously accept both the metal support structures of membrane modules and titanium anodes, eliminating the need for water treatment plants to seek separate disposal channels for these two types of recyclable materials. For water treatment facilities using DSA anodes for electrochemical advanced oxidation, the failure cycle of the anode coating and the membrane replacement cycle are often out of sync. This means that over many years of operation, water treatment plants will generate multiple batches of titanium anode waste; establishing a stable recycling partnership is more efficient than conducting one-off transactions.


Key Differences in Regional Practices


The core of Brazil’s experience lies in low-cost implementation. Research conducted by UFMG focused specifically on rural water supply scenarios under the Programa �gua Doce framework, using membranes recovered from membrane systems to treat groundwater with high iron content. With an acquisition cost of $30.50 per membrane, the annual savings amount to approximately $1,954.80—a significant economic benefit for small-scale desalination plants in the semi-arid regions of northeastern Brazil. The Brazilian study also validated the life cycle assessment rankings: direct reuse and conversion to ultrafiltration membranes performed best on environmental and social dimensions, while component recycling was the cheapest option at $0.36 per unit; all membrane recycling scenarios outperformed landfilling.


The core of Chile’s experience lies in screening challenges under pressure to scale up. In seawater desalination applications, membrane replacement cycles typically range from three to five years, with annual replacement rates reaching as high as 20 percent. As of November 2025, the cities of Antofagasta and Mejillones were relying entirely on reverse osmosis desalination for their water supply. The core challenge facing Chilean researchers was clearly identified: how to identify which membranes still retain sufficient structural integrity to undergo the membrane regeneration process. CCTVal is designing experimental modules to perform this screening. Chile’s technical approach involves an advanced oxidation process aided by ozone and ultrasound, which differs from Brazil’s NaClO approach.


Common Operational Pitfalls


Pitfall 1: Equating the recovery of flux after cleaning with the membrane’s suitability for reuse. Membrane cleaning accelerates polyamide degradation, a form of latent damage that may not become apparent until the first few months of reuse. Feedback from the secondhand membrane market indicates that while water quality remains acceptable shortly after installing refurbished membranes, water production plummets within one to three months.


Pitfall 2: Ignoring the membrane’s historical operating conditions. Among membranes retired from the same batch, the remaining service life can vary significantly depending on their previous operating conditions. The industry-recommended practice is to determine a selective reuse strategy based on the membrane’s historical operating conditions and post-cleaning performance. Membranes from electroplating or chemical wastewater treatment may contain residual heavy metals or organic compounds, posing risks of incomplete cleaning or material damage.


Pitfall 3: The lack of traceability in the used membrane market. Secondhand membranes are no longer covered by the original manufacturer’s warranty. Many low-priced options on the market are units scrapped due to residual chlorine oxidation, with irreversible damage to the membrane’s desalination layer. The use of secondhand membranes is strictly prohibited in high-standard water production projects such as those for food, drinking water, pharmaceuticals, and ultrapure water. Reverse osmosis membranes have a design life of three to five years; membranes retired early—after one to two years of use—offer the best cost-effectiveness, while membranes used for more than five years carry a significantly increased risk of material degradation.


Pitfall Four: Neglecting the economic viability of the transportation radius. Transportation costs for membrane recovery directly impact economic feasibility. A study by UFMG set the transportation distance at 50 kilometers as the evaluation threshold; beyond this range, the economic advantages of membrane recovery may be offset by logistics costs.

Tank Your Inquiry! We will contact you within 24 hours.

OK

Get the Recycling Price

  • Name*
  • Email Address*
  • Phone/Whatsapp
  • Country
  • Message*
  • Submit